"EA offline" although MetaTrader is open and everything is set up

What to check, in order, when the journal shows "EA offline" although Algo Trading is on and the WebRequest addresses are added.

2 min read

At the top of the journal, EA offline means that ProTradingData is not keeping its real-time connection with ProTradingLabs. The Algo Trading button has nothing to do with it: it allows orders, not the connection. Here is what to check, in order.

1. Is ProTradingData running on a chart?

In MetaTrader, the EA must be on a chart of the account, with its panel visible in the top-left corner. If there is no panel, drag ProTradingData onto a chart from the Navigator. MetaTrader must stay open, and the computer on, without going to sleep.

2. Read the panel message

The EA panel gives the cause in plain words (in French):

Panel messageWhat to do
« Mise à jour obligatoire » (update required)Install the new version: see How do I update my ProTradingLabs EAs?. An old version is refused as soon as a new one is out.
« ProTradingData tourne déjà sur un autre graphique de ce compte » (already running on another chart)Keep a single ProTradingData per account and remove the other one.
« MetaTrader bloque la connexion en temps réel » (MetaTrader blocks the real-time connection)Add http://ws.protradinglabs.com, with http and not https, in Tools › Options › Expert Advisors, then restart the EA.
« MetaTrader interdit à l'EA de joindre ProTradingLabs » (MetaTrader forbids the EA to reach ProTradingLabs)Also add https://api.protradinglabs.com in the same place, then restart the EA.
« Le serveur ProTradingLabs a renvoyé une erreur (HTTP 1009) »A certificate is missing from Windows: see HTTP error 1009.
« MetaTrader n'est pas connecté au broker » (not connected to the broker)See My MetaTrader account is disconnected.
« Connexion en temps réel coupée » (real-time connection lost)Check your internet connection, and that no firewall or antivirus blocks MetaTrader. The EA reconnects on its own.

The addresses must be copied exactly, with no space or trailing slash. After changing the options, remove the EA from the chart and add it again.

3. Wait a few seconds

The journal goes online a few seconds after the EA starts, and offline about 30 seconds after a disconnection. Reload the journal page if the indicator does not change.

If everything is correct

The panel says everything works, but the journal stays offline? The outage is then probably on our side. There is nothing to do: the EA reconnects on its own as soon as the service is back, and the trades made in the meantime reach the journal. If it lasts more than an hour, contact support with a screenshot of the EA panel and of the MetaTrader Experts tab.

To keep the journal up to date without leaving a computer on, use cloud sync: see My MetaTrader account is disconnected.

Did this article help?
Can't find the answer?Email support, or sign in to ask the help assistant.